Pre-Deployment Robustness Stress Testing for CT Segmentation Systems Using Clinically Motivated Multi-Corruption Augmentation 文章

ArXiv CS.CV2026-06-02NEWSen作者: CholMin Kang, Jonghyun Chung, Amanpreet Kaurb, Nagesh Gulkotwarb, Arthi Sivasankaranb

摘要

arXiv:2606.00491v1 Announce Type: new Abstract: Deep learning-based CT segmentation systems often achieve high accuracy on clean benchmark images, but their performance may degrade under heterogeneous clinical imaging conditions such as noise, resolution loss, contrast variation, intensity shift, and artifacts. This instability can limit reliable deployment in real-world medical imaging workflows. We propose Robustness via Augmented Multi-corruption Pipeline (RAMP), a robustness-oriented augmentation framework for CT segmentation. RAMP combines anatomically constrained spatial perturbations, CT intensity transformations, and stochastic multi-corruption composition to expose models to clinically plausible image degradation during training. Across two CT segmentation evaluation settings, RAMP achieved the strongest corrupted-image performance and the smallest clean-to-corrupted robustness gap. In the five-organ noisy evaluation benchmark, RAMP improved mean corrupted Dice from 0.