摘要
arXiv:2606.01229v1 Announce Type: new Abstract: During green building design, computer-aided energy assessment is widely used to improve efficiency and achieve overall optimization. This paper presents a platform that combines Building Information Modeling (BIM), sensor operational data, and advanced simulation workflows using robust algorithms. The platform uses a multi-layer service architecture with dynamic energy simulation and evolutionary multi-objective optimization, connected via a high-performance C++ core and adaptive agent models. A mid-rise office building was selected as the case study. Five representative areas were chosen to collect data on building envelope characteristics and occupancy patterns. After preprocessing, missing sensor data accounted for 3.2% of annual records, and all variables were standardized using 15-minute interpolation. After 40 optimization rounds, annual energy consumption per square meter dropped by 29.3% from 315 kWh/m2 to 223 kWh/m2.